An electric patio heater must match its rated supply voltage and have a suitable electrical installation. For a resistive heater, watts divided by volts gives an approximate full-output current. That calculation describes the load; it does not select the breaker, cable or outlet.
Read the nameplate before planning the circuit
Record the exact model, rated voltage, maximum wattage or current, and whether it is supplied with a plug or requires fixed wiring. A similar-looking heater may be sold in different voltage versions. A plug adapter does not convert one supply voltage into another.
| Example or calculation | Rated power / supply | Full-output current |
|---|---|---|
| Dr. Infrared Heater DR-238, US manual | 1500W / 120V nominal | 12.5A calculated |
| Bromic Tungsten BH0420030, North America | 2000W / 240V | 8.3A listed |
| Bromic Tungsten BH0420031, North America | 3000W / 240V | 12.5A listed |
| Bromic Tungsten BH0420033, North America | 6000W / 240V | 25A listed |
Sources: the DR-238 manual, specification table and Bromic Tungsten US manual, North America model table. These are model examples, not a recommendation to connect any of them to an existing circuit without checking it.
What 120V versus 240V actually changes
At the same wattage, higher voltage means lower current: a hypothetical 1500W load is 12.5A at 120V or 6.25A at 240V. It still uses 1.5kWh during one hour at full power. Voltage by itself does not make the same wattage cheaper to run.
Higher-output patio heaters are available with fixed electrical installations, but neither “240V” nor “hardwired” guarantees comfortable coverage. Match the heat pattern and seating layout as well as the supply. The infrared troubleshooting guide distinguishes weak apparent warmth from a heater that is not producing heat.
Can a 1500W heater use a 15A circuit?
The arithmetic alone cannot approve that installation. At 120V, 1500W is 12.5A before considering other loads or the rules applicable to that heater and circuit. Two such heaters total 25A at full output; plugging them into different receptacles does not prove they are on different circuits.
For a plug-in model, follow the appliance instructions and have an electrician assess an uncertain circuit. The DR-238 instructions require direct wall-receptacle connection and prohibit extension cords and power strips. For fixed equipment, Bromic requires licensed, authorized installation under applicable codes. A general wire-gauge chart cannot account for all installation conditions.
Do not replace a tripping breaker with a larger one. Stop using a heater on a circuit that trips and have the cause checked. A trip can reflect a problem that a larger breaker would not solve.
Estimate operating cost with your own rate
Cost = rated kW × hours at that output × electricity rate per kWh. At an illustrative $0.20/kWh, one hour of continuous full-output operation costs:
| Heater power | Energy in one hour | Illustrative cost |
|---|---|---|
| 1500W | 1.5kWh | $0.30 |
| 3000W | 3kWh | $0.60 |
| 6000W | 6kWh | $1.20 |
These are arithmetic examples, not current local tariffs. Use your bill’s relevant rate. Lower settings or cycling may reduce consumption, but do not assume an exact saving without knowing actual runtime and power. Installation charges and fixed utility fees are separate.
Give the installer a concrete brief
- The model’s rating label and installation manual.
- The number of heaters and whether they will operate together.
- The desired mounting and control locations, plus the seating layout.
- Whether the location is outdoors or exposed to moisture.
- Existing supply details, if known—without opening electrical enclosures to obtain them.
Ask the installer to confirm supply compatibility, circuit capacity, protective devices, weather suitability, controls and mounting requirements. Choose a heater after those requirements are understood. The useful shopping number is its load; the final installation is a separate decision.